Programmable Transformer Rectifier for Railway Inverter Testing
A cascaded transformer-rectifier system providing programmable 900–1800 VDC and 230 kW continuous power for railway inverter testing, with integrated real-time control and SCADA.

- Delivery year
- 2025
- Application
- Post-assembly functional verification and selected type and routine testing of railway auxiliary inverters at production testing facilities.
In 2025, NSAD designed and delivered a programmable transformer-rectifier system for post-assembly functional verification and selected type and routine testing of railway auxiliary inverters. The 300 kVA system provides a programmable 900–1800 VDC main output, with 230 kW continuous output power, while 250 kW peak DC output was separately recorded during type testing.
A cascaded transformer-rectifier architecture enables programmable DC power-output simulation of representative railway traction supply conditions, including operation around a nominal 1,500 VDC system. Controlled power-interruption and restoration simulation allows converter behavior to be evaluated under defined input-supply scenarios, supporting repeatable production testing.
Alongside the main high-voltage output, a regulated 77–132 VDC, 2.2 kW auxiliary supply supports simulation of onboard battery-supply conditions. This enables auxiliary power requirements to be addressed within the same inverter testing setup.
The system uses NSAD’s MRCU-3U embedded controller platform for real-time control, 10 kHz monitoring and protection, and integrated electrical protection and safety interlocking. SCADA provides supervisory monitoring, operator control, and test-status visualization, while time-critical monitoring and protection are handled by the embedded controller.
RS-485 and CANopen interfaces enable remote monitoring and integration with external testing equipment, complemented by remote data logging. Relevant testing activities reference IEC/EN 61287-1, JIS E 5008, and EN 50163. Together, these capabilities provide a controlled, monitored, and protected power source for railway converter verification.
Technical Highlights
- Input system rating
- 300 kVA
- Programmable main DC output
- 900–1800 VDC
- Continuous output power
- 230 kW
- Peak DC output recorded during type testing
- 250 kW
- Regulated battery-simulation supply
- 77–132 VDC
- Auxiliary output power
- 2.2 kW
- Power simulation architecture
- Cascaded transformer-rectifier
- Real-time monitoring and protection rate
- 10 kHz
- SCADA controller platform
- NSAD MRCU-3U
- Remote monitoring interfaces
- RS-485 / CANopen